Catalog
Clinical Area
Bone & Mineral Metabolism
Endocrinology
Hypertension
Infectious diseases
Advanced search
Clinical area
Bone & Mineral Metabolism
Endocrinology
Hypertension
Infectious diseases
Product line
EBV
Hepatitis
TORCH
Tuberculosis
Others
Diabetes
Fertility
General endocrinology
Hypertension
Gastroenterology
SPQ Protein
TDM
Hypertension
Hematology
Growth
Thyroid
Bone turnover
PTH
Vitamin D
Rheumatology
Accessories
Technology
CLIA
ELISA
IFA
RIA
WESTERN BLOT
Sample type
Serum and/or Plasma
Urine
Stool
Cerebro Spinal Fluid (CSF)
Other
Search
9
products found
You are in
Hypertension
/
All
Hypertension
Filter results:
Create your PDF
ACTH IRMA
27130/130 Beads
Intended Use
For the quantitative determination of human Adrenocorticotropic Hormone (ACTH) in EDTA plasma
Label
125I
Method
RIA Coated Bead
No. of Standards
6
Incubation
Overnight/RT
Sample Type
EDTA Plasma
Sample Size
200 µL
Comments
In Vitro Diagnostic Use
GammaCoat™ Plasma Renin Activity
CA1533/100 Tubes
Intended Use
Quantitative determination of Plasma Renin Activity (PRA) by the Radioimmunoassay of generated Angiotensin I
Label
125I
Method
RIA Coated Tubes
No. of Standards
6
Incubation
3 hours/RT
Sample Type
EDTA Plasma
Sample Size
1000 µL
Comments
In Vitro Diagnostic Use
GammaCoat™ Plasma Renin Activity
CA1553/500 Tubes
Intended Use
Quantitative determination of Plasma Renin Activity (PRA) by the Radioimmunoassay of generated Angiotensin I
Label
125I
Method
RIA Coated Tubes
No. of Standards
6
Incubation
3 hours/RT
Sample Type
EDTA Plasma
Sample Size
1000 µL
Comments
In Vitro Diagnostic Use
LIAISON® Direct Renin
310350
Intended Use
Quantitative determination of renin in human EDTA plasma.
Material provided
Reagent Integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
2.1 pg/mL
Calibrators
Included
No. of Calibrators
2
Measuring Range
2.1-300 pg/mL
Sample Type
EDTA Plasma
Sample Size
205 µL
Comments
In Vitro Diagnostic Use
LIAISON® Direct Renin Control Set
310351
Material provided
5 determinations per vial X 2 levels X 4 vials each
LIAISON® Aldosterone
310450
Intended Use
Quantitative determination of aldosterone in human serum, EDTA plasma and urine samples.
Material provided
Reagent Integral for 100 determinations
Method
Competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit
3.0 ng/dL
Calibrators
Included
No. of Calibrators
2
Measuring Range
3-100 ng/dL
Sample Type
Serum, EDTA Plasma and Urine
Sample Size
100 µL Serum, EDTA plasma; 100 µL hydrolyzed neutralized urine
Comments
In Vitro Diagnostic Use
LIAISON® Aldosterone Control Set
310451
Material provided
40 determinations per vial X 2 levels X 2 vials each
LIAISON® ALDO Neutralization Buffer
310452
Material provided
2 vials with 25 mL each
LIAISON® Aldosterone Calibration Verifiers
310453
Material provided
4 vials with 4.5 mL each