25 products found

LIAISON® IGF-1

313231

Intended Use For the quantitative determination of IGF-1 in human serum
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 10 ng/mL
Calibrators Included
No. of Calibrators 2 levels lyophilized
Measuring Range 10-1200 ng/mL
Sample Type Serum
Sample Size 20 µL
Comments In Vitro Diagnostic Use

LIAISON® C-Peptid

316171

Intended Use For the quantitative determination of C-Peptide in human serum
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.1 ng/mL
Calibrators Included
No. of Calibrators 2
Measuring Range 0.1-30 ng/mL
Sample Type Serum
Sample Size 50 µL
Comments In Vitro Diagnostic Use

LIAISON® FT3

311531

Intended Use For the quantitative determination of free triiodothyronine (FT3) in human serum
Material provided Reagent integral for 100 determinations
Method 2 –step SPALT chemiluminescent immunoassay using coated magnetic particles
Detection Limit 1.1 pg/mL
Calibrators Included
No. of Calibrators 2
Measuring Range 1.1-30 pg/mL
Sample Type Serum
Sample Size 50 µL
Comments In Vitro Diagnostic Use

LIAISON® FT4

311611

Intended Use For the quantitative determination of free thyroxine (FT4) in human serum
Material provided Reagent integral for 100 determinations
Method 1 –step SPALT chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.29 ng/dL
Calibrators Included
No. of Calibrators 2
Measuring Range 0.29-7.7 ng/dL
Sample Type Serum
Sample Size 50 µL
Comments In Vitro Diagnostic Use

LIAISON® TSH

311211

Intended Use For the quantitative determination of thyroid stimulating hormone (TSH) in human serum
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.02 mIU/L
Calibrators Included
No. of Calibrators 2
Measuring Range 0.02-90 mIU/mL
Sample Type Serum
Sample Size 200 µL
Comments In Vitro Diagnostic Use

LIAISON® Thyroid Controls - Hyper

389239

Material provided 4 vials x 5 mL each

LIAISON® Thyroid Controls - Hypo

389219

Material provided 4 vials x 5 mL each

LIAISON® Thyroid Controls - Normal

389229

Material provided 4 vials x 5 mL each

LIAISON® LH

312201

Intended Use For the quantitative determination of luteinising hormone (LH) in human serum
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.4 mIU/mL
Calibrators Included
No. of Calibrators 2
Measuring Range 0.4-125 mIU/mL
Sample Type Serum
Sample Size 50 µL
Comments In Vitro Diagnostic Use

LIAISON® FSH

312251

Intended Use For the quantitative determination of follicle-stimulating hormone (FSH) in human serum
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.65 mIU/mL
Calibrators Included
No. of Calibrators 2
Measuring Range 0.65-200 mIU/mL
Sample Type Serum
Sample Size 25 µL
Comments In Vitro Diagnostic Use

LIAISON® Prolactin xt

312171

Intended Use For the quantitative determination of prolactin in human serum, as an aid in the diagnosis and treatment of pituitary disorders.
Material provided Reagent integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 4 mIU/mL
Calibrators Included
No. of Calibrators 2 levels lyophilized
Measuring Range 4-8000 mIU/mL
Sample Type Serum
Sample Size 25 µL
Comments In Vitro Diagnostic Use

LIAISON® Testosterone

310410

Intended Use For the quantitative determination of testosterone in human serum and EDTA plasma
Material provided Reagent integral for 100 determinations
Method Competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.16 ng/mL
Calibrators Included
No. of Calibrators 2 levels; liquid
Measuring Range 0.16 – 15.0 ng/mL
Sample Type Serum/EDTA Plasma
Sample Size 100 µL
Comments In Vitro Diagnostic Use

LIAISON® Control Testosterone

310411

Material provided 2 levels x 2 vials each, 60 determinations total

LIAISON® Estradiol II Gen

310680

Intended Use For the quantitative determination of estradiol in human serum.
Material provided Reagent integral for 100 determinations
Method Two-step competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit 16.2 pg/mL
Calibrators Included
No. of Calibrators 2 levels; liquid
Measuring Range 16.2-1000 pg/mL
Sample Type Serum
Sample Size 100 µL
Comments In Vitro Diagnostic Use

LIAISON® Control Estradiol II Gen

310681

Material provided 2 levels x 2 vials each, 80 determinations total

LIAISON® Progesterone II Gen

310690

Intended Use For the quantitative determination of progesterone in human serum.
Material provided Reagent integral for 100 determinations
Method Two-step competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.17 ng/mL
Calibrators Included
No. of Calibrators 2 levels; liquid
Measuring Range 0.17-60 ng/mL
Sample Type Serum
Sample Size 40 µL
Comments In Vitro Diagnostic Use

LIAISON® Control Progesterone II Gen

310691

Material provided 2 levels x 2 vials each, 54 determinations total

LIAISON® hGH

310340

Intended Use For the quantitative determination of human Growth Hormone in human serum
Material provided Reagent Integral for 100 determinations
Method Sandwich chemiluminescence immunoassay using coated magnetic particles
Detection Limit 0.1 ng/mL
Calibrators Included
No. of Calibrators 2 levels; lyophilized
Measuring Range 0.1-80 ng/mL
Sample Type Serum
Sample Size 30 uL
Comments In Vitro Diagnostic Use

LIAISON® Control hGH

310341

Material provided Two levels x 2 vials each, 40 determination total

LIAISON®Insulin

310360

Intended Use For the quantitative determination of Insulin in human serum specimens
Material provided Reagent Integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 0.87 µIU/mL
Calibrators Included
No. of Calibrators 2 levels; lyophilized
Measuring Range 0.87-500 µlU/mL
Sample Type Serum
Sample Size 60 µL
Comments In Vitro Diagnostic Use

LIAISON®Control Insulin

310631

Material provided Two levels x 2 vials each 15 determinations per vial

LIAISON®XL HCG

312321

Intended Use For the quantitiative determination of total human chorionic gonadotropin in human serum specimens
Material provided Reagent Integral for 100 determinations
Method Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit 1.5 mIU/mL
Calibrators Included
No. of Calibrators 2 levels
Measuring Range 1.5-10,000 mIU/mL
Sample Type Serum
Sample Size 30 uL
Comments In Vitro Diagnostic Use

LIAISON® Endocrinology Diluent

319133

Material provided 4 vials with 4.5 mL each

Vitamin B12/Folate

06B257117/100 Tubes

Intended Use Simultaneous quantitative determination of Vitamin B12 and Folate
Label 125 I, 57CO
Method RIA Dual Isotope
No. of Standards 6
Incubation 15 min + 10 min + 1 hr/RT
Sample Type Serum/EDTA Plasma/Whole Blood
Sample Size 200 µL
Comments In Vitro Diagnostic Use

TSH-CTK 3

309-100/100 Wells

Intended Use For the quantitative determination of Thyroid Stimulating Hormone (hTSH)
Label 125 I
Method RIA Coated Tube
No. of Standards 7
Incubation 60 min/RT
Sample Type Serum
Sample Size 100 µL
Comments In Vitro Diagnostic Use