Company
Research & Development
Products & Solutions
Investors
Congresses & Events
Media
Career
Catalog
Clinical Area
Bone & Mineral Metabolism
Endocrinology
Hypertension
Infectious diseases
Advanced search
Clinical area
Bone & Mineral Metabolism
Endocrinology
Hypertension
Infectious diseases
Product line
EBV
Hepatitis
TORCH
Tuberculosis
Others
Diabetes
Fertility
General endocrinology
Hypertension
Gastroenterology
SPQ Protein
TDM
Hypertension
Hematology
Growth
Thyroid
Bone turnover
PTH
Vitamin D
Rheumatology
Accessories
Technology
CLIA
ELISA
IFA
RIA
WESTERN BLOT
Sample type
Serum and/or Plasma
Urine
Stool
Cerebro Spinal Fluid (CSF)
Other
Search
25
products found
You are in
Endocrinology
/
All
Diabetes
Fertility
General endocrinology
Hematology
Growth
Thyroid
Filter results:
Create your PDF
LIAISON® IGF-1
313231
Intended Use
For the quantitative determination of IGF-1 in human serum
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
10 ng/mL
Calibrators
Included
No. of Calibrators
2 levels lyophilized
Measuring Range
10-1200 ng/mL
Sample Type
Serum
Sample Size
20 µL
Comments
In Vitro Diagnostic Use
LIAISON® C-Peptid
316171
Intended Use
For the quantitative determination of C-Peptide in human serum
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.1 ng/mL
Calibrators
Included
No. of Calibrators
2
Measuring Range
0.1-30 ng/mL
Sample Type
Serum
Sample Size
50 µL
Comments
In Vitro Diagnostic Use
LIAISON® FT3
311531
Intended Use
For the quantitative determination of free triiodothyronine (FT3) in human serum
Material provided
Reagent integral for 100 determinations
Method
2 –step SPALT chemiluminescent immunoassay using coated magnetic particles
Detection Limit
1.1 pg/mL
Calibrators
Included
No. of Calibrators
2
Measuring Range
1.1-30 pg/mL
Sample Type
Serum
Sample Size
50 µL
Comments
In Vitro Diagnostic Use
LIAISON® FT4
311611
Intended Use
For the quantitative determination of free thyroxine (FT4) in human serum
Material provided
Reagent integral for 100 determinations
Method
1 –step SPALT chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.29 ng/dL
Calibrators
Included
No. of Calibrators
2
Measuring Range
0.29-7.7 ng/dL
Sample Type
Serum
Sample Size
50 µL
Comments
In Vitro Diagnostic Use
LIAISON® TSH
311211
Intended Use
For the quantitative determination of thyroid stimulating hormone (TSH) in human serum
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.02 mIU/L
Calibrators
Included
No. of Calibrators
2
Measuring Range
0.02-90 mIU/mL
Sample Type
Serum
Sample Size
200 µL
Comments
In Vitro Diagnostic Use
LIAISON® Thyroid Controls - Hyper
389239
Material provided
4 vials x 5 mL each
LIAISON® Thyroid Controls - Hypo
389219
Material provided
4 vials x 5 mL each
LIAISON® Thyroid Controls - Normal
389229
Material provided
4 vials x 5 mL each
LIAISON® LH
312201
Intended Use
For the quantitative determination of luteinising hormone (LH) in human serum
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.4 mIU/mL
Calibrators
Included
No. of Calibrators
2
Measuring Range
0.4-125 mIU/mL
Sample Type
Serum
Sample Size
50 µL
Comments
In Vitro Diagnostic Use
LIAISON® FSH
312251
Intended Use
For the quantitative determination of follicle-stimulating hormone (FSH) in human serum
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.65 mIU/mL
Calibrators
Included
No. of Calibrators
2
Measuring Range
0.65-200 mIU/mL
Sample Type
Serum
Sample Size
25 µL
Comments
In Vitro Diagnostic Use
LIAISON® Prolactin xt
312171
Intended Use
For the quantitative determination of prolactin in human serum, as an aid in the diagnosis and treatment of pituitary disorders.
Material provided
Reagent integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
4 mIU/mL
Calibrators
Included
No. of Calibrators
2 levels lyophilized
Measuring Range
4-8000 mIU/mL
Sample Type
Serum
Sample Size
25 µL
Comments
In Vitro Diagnostic Use
LIAISON® Testosterone
310410
Intended Use
For the quantitative determination of testosterone in human serum and EDTA plasma
Material provided
Reagent integral for 100 determinations
Method
Competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.16 ng/mL
Calibrators
Included
No. of Calibrators
2 levels; liquid
Measuring Range
0.16 – 15.0 ng/mL
Sample Type
Serum/EDTA Plasma
Sample Size
100 µL
Comments
In Vitro Diagnostic Use
LIAISON® Control Testosterone
310411
Material provided
2 levels x 2 vials each, 60 determinations total
LIAISON® Estradiol II Gen
310680
Intended Use
For the quantitative determination of estradiol in human serum.
Material provided
Reagent integral for 100 determinations
Method
Two-step competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit
16.2 pg/mL
Calibrators
Included
No. of Calibrators
2 levels; liquid
Measuring Range
16.2-1000 pg/mL
Sample Type
Serum
Sample Size
100 µL
Comments
In Vitro Diagnostic Use
LIAISON® Control Estradiol II Gen
310681
Material provided
2 levels x 2 vials each, 80 determinations total
LIAISON® Progesterone II Gen
310690
Intended Use
For the quantitative determination of progesterone in human serum.
Material provided
Reagent integral for 100 determinations
Method
Two-step competitive chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.17 ng/mL
Calibrators
Included
No. of Calibrators
2 levels; liquid
Measuring Range
0.17-60 ng/mL
Sample Type
Serum
Sample Size
40 µL
Comments
In Vitro Diagnostic Use
LIAISON® Control Progesterone II Gen
310691
Material provided
2 levels x 2 vials each, 54 determinations total
LIAISON® hGH
310340
Intended Use
For the quantitative determination of human Growth Hormone in human serum
Material provided
Reagent Integral for 100 determinations
Method
Sandwich chemiluminescence immunoassay using coated magnetic particles
Detection Limit
0.1 ng/mL
Calibrators
Included
No. of Calibrators
2 levels; lyophilized
Measuring Range
0.1-80 ng/mL
Sample Type
Serum
Sample Size
30 uL
Comments
In Vitro Diagnostic Use
LIAISON® Control hGH
310341
Material provided
Two levels x 2 vials each, 40 determination total
LIAISON®Insulin
310360
Intended Use
For the quantitative determination of Insulin in human serum specimens
Material provided
Reagent Integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
0.87 µIU/mL
Calibrators
Included
No. of Calibrators
2 levels; lyophilized
Measuring Range
0.87-500 µlU/mL
Sample Type
Serum
Sample Size
60 µL
Comments
In Vitro Diagnostic Use
LIAISON®Control Insulin
310631
Material provided
Two levels x 2 vials each 15 determinations per vial
LIAISON®XL HCG
312321
Intended Use
For the quantitiative determination of total human chorionic gonadotropin in human serum specimens
Material provided
Reagent Integral for 100 determinations
Method
Sandwich chemiluminescent immunoassay using coated magnetic particles
Detection Limit
1.5 mIU/mL
Calibrators
Included
No. of Calibrators
2 levels
Measuring Range
1.5-10,000 mIU/mL
Sample Type
Serum
Sample Size
30 uL
Comments
In Vitro Diagnostic Use
LIAISON® Endocrinology Diluent
319133
Material provided
4 vials with 4.5 mL each
Vitamin B12/Folate
06B257117/100 Tubes
Intended Use
Simultaneous quantitative determination of Vitamin B12 and Folate
Label
125 I, 57CO
Method
RIA Dual Isotope
No. of Standards
6
Incubation
15 min + 10 min + 1 hr/RT
Sample Type
Serum/EDTA Plasma/Whole Blood
Sample Size
200 µL
Comments
In Vitro Diagnostic Use
TSH-CTK 3
309-100/100 Wells
Intended Use
For the quantitative determination of Thyroid Stimulating Hormone (hTSH)
Label
125 I
Method
RIA Coated Tube
No. of Standards
7
Incubation
60 min/RT
Sample Type
Serum
Sample Size
100 µL
Comments
In Vitro Diagnostic Use